set l2OnDrops

Prev Next

This command configures the settings for Layer 2 mode on drops.

Syntax:

set l2OnDrops (enable|disable|sensitivity-level)

Parameter Description
enable Puts the Sensor to Layer 2 mode when high drops are seen
disable Disables Layer 2 mode on drops
sensitivity-level Configures the sensitivity level for Layer 2 mode on drops
Sample Output:

intruShell@john> set l2OnDrops enable

intruShell@john> show l2OnDropsConfig

L2OnDrops Stats: Enabled

Note

To view the status of set l2OnDrops, provide show l2OnDropsConfig command.

Applicable to:

NS-series Sensors

Note

  • The Layer 2 mode must be 'ON' to configure set l2OnDrops (enable|disable|sensitivity-level).
  • To automatically restore the Sensor to normal state, configure latency-monitor restore-inline command. For more information, refer to latency-monitor restore-inline.
  • For more information on set l2OnDrops sensitivity-level command, refer to set l2OnDrops sensitivity-level.
  • For more information on show l2OnDropsConfig command, refer to show l2OnDropsConfig.