The Common Settings option enables you to determine the breadth and detail of fault information that will be sent via email, pager, or script. You can configure a suppression time within which faults are held pending Acknowledge or Delete actions — or automatic clearing events from the source — within Operational Status.
To manage fault notification details, do the following:
Steps:
Select Manager → <Admin Domain Name> → Setup → Notification → Faults → Common Settings (same for Central Manager).
Fill in the following fields:
Admin Domains
Current — Send only faults for the current domain. This is always selected for the current domain.
Children — Send faults for all child domains of the current domain
Notification Scope— If Sensor interfaces have been delegated to a child domain, faults can be set to display by the Admin domain in which the delegated interface resides, rather than by the domain where the Sensor is controlled.
Entire Device — Faults based on Sensor-domain relationship
Individual interface — Faults based on interface-domain relationship
Suppression Time — The amount of time to suppress system faults before forwarding. The default and minimum value is 2 minutes.
Note
Suppression Time can only be set within the root admin domain.
Click Save.