The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

Setting the Sensor throughput threshold for specific devices

Prev Next

Follow this procedure for setting the Sensor throughput threshold for a specific device within a domain.

  1. Select Devices → <Admin Domain Name> → Devices → <Device Name> → Setup → Performance Monitoring → Thresholds.

    Thresholds sub-tab
    Thresholds sub-tab


  2. Select Device Throughput Usage in the drop down list against Metric.

  3. Enter the required threshold percentage in the Threshold [%] column (this value should be higher than the value in the Reset Threshold [%] column).

  4. Select Generate Fault? generate fault.

  5. Click Save.

    Note

    Click Defaults to set the threshold settings to the default values. Under Usage in the context of the throughput usage threshold is a 'falling threshold'. A fault is generated when the throughput % drops below a certain value. This is helpful on very busy networks, where a certain amount of traffic is always expected to be seen. This type of fault is a good indication that there is a communication problem on the network.