The status command shows Sensor system status, such as System Health, Manager communication, signature set details, total number of alerts detected, and total number of alerts sent to the Manager.
This command has no parameters.
Syntax:
status
Sample Output:
For Sensor, the output is as shown:
intruShell@NS3200_FIPS> status
[Sensor]
System Initialized : yes
System Health Status : good
Layer 2 Status : normal (IDS/IPS)
Installation Status : complete
IPv6 Status : Dont Parse and Allow Inline
Reboot Status : Not Required
Guest Portal Status : up
Hitless Reboot : Available
Last Reboot reason : unknown
[Signature Status]
Present : yes
Version : 11.10.10.5
Power up signature : good
Geo Location database : Present
DAT file : Present
DAT file Version : 3756.0
[Manager Communications]
Trust Established : yes (Self Signed cert support)
Alert Channel : up
Log Channel : up
Authentication Channel : up
Last Error : None
Alerts Sent : 14
Logs Sent : 42
[Alerts Detected]
Signature : 0
Alerts Suppressed : 0
Scan : 0
Denial of Service : 0
Malware : 14
[TIS Communication]
Status : down
IP : 0.0.0.0
Port(Secure) : 8505
FIPS Mode : Enabled
Admin SSH/Console Access: Enabled
Note
If there is a failure in establishing trust relationship between the Sensor and Manager due to mismatch in shared secret key, the
Last Errordisplays the messageAlert Channel - Install Keys Mismatch. In such an instance, check the shared secret key on the Manager and set it on the Sensor usingset sensor sharedsecretkeycommand.