This section assumes the following for deploying the Virtual Sensor for scenario 2.
- The ESX server meets the requirements as discussed in Requirements for deploying the Virtual Sensor.
- You have the privileges on the ESX server to add and modify vSwitches and port groups.
- You have installed the Virtual Sensor and established trust with the Manager successfully. As an example in this scenario, the management port is connected to vSwitch2.
- As an example, this section uses the IPS-VM600 Virtual Sensor to explain the deployment.
- This scenario involves only a Sensor monitoring port pair deployed in inline fail-closed mode.
- This section uses only the vSphere Client for configurations on the ESX.
Task
- Create vSwitch1 for connecting Sensor monitoring port 2 and the 10.10.10.16 server.
- Modify vSwitch0 to connect monitoring port 1.
- Assign the corresponding switch port group (promiscuous mode) that you created in step 1 to monitoring port 2.
- Change the switch port group for the 10.10.10.16 server such that it is now connected to vSwitch1.
- Assign the corresponding switch port group (promiscuous mode) that you created in step 2 to monitoring port 1.
-
Verify if you have deployed the Virtual Sensor correctly and whether it is inspecting traffic.
Refer to Verify the deployment.